Product Features
Control Panel
- 8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, zone anding and a variety of other features
- Up to 48 points of up to 32 zones with optional zone-expansion modules 4- zone keypad EZMs (built-in)
- Including up to 2 2-wire fire zones
- Up to 32 individually coded users, each with a programmable authority level
- 3 on-board relay outputs, expandable 24 external relay outputs
- 3 keypad panics: fire, police and auxiliary
- 2 independent area partitions
- Up to 7 separate access stations by up to 32 users
- Up to 24 separately-addressable X-10 devices with the GEM-X10KIT
- English-language prompts and system status messages from choice of keypad (8) models
- User-customized zone descriptions, reprogrammable as required
- 2-wire and 4-wire smoke detectors
- Reports alarms, restores and troubles by zone
- 255 event schedule
- 800 event log
- Overview mode permits monitoring and control of total system from one keypad
- 2 programmable entry delay times
- Interior-bypass group
- Dynamic battery test interrupts charging and places battery under load every four hours
- Chime by zone; programmable duration
- Non-volatile RAM retains memory during power losses
- Quickloader programmable
- Auto-Download Log
- Exclusive V.A.L.I.D. feature (Verifying Automatic Line Integrity Diagnostic) reduces false alarms due to changes in line resistance
Communicator
- Compatible with all major receiver formats, including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2 Express and Point ID
- Rotary dial and TouchTone with Rotary backup
- 3 20-digit telephone numbers
- Backup reporting, double reporting; split reporting
- 32 User codes with opening/closing reporting by user
- AC failure reporting with programmable report delay
- Supervised telephone line cut with programmable delay
- Pager capability
Technical Details
- Panel Dimensions: 12.375(L) x 13.875(W) x 3.55(H) inches (without cover)
- Operating Temperature: 32 to 120 degrees F (0 to 49 degrees C)
- Input Power: 16.5VAC via CLASS 2 Plug-In 40VA or 50VA Transformer
- Loop Voltage: 10-13VDC
- Loop Current: 2.4mA with 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zones; 1.4 mA using a 3.9K Ohm resistor (Model EOL 3.9K) with Zone Doubling
- Loop Resistance: 300W max.; 50W for 2-wire smoke-detector zones
- Relay Outputs (Burglary; Reset; Aux): Wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts; see Wiring Diagram), SPDT contacts 24Vdc, 2A, 0.6 PF
- Auxiliary Power Output: 12VDC regulated
- Remote Power Output: 12VDC regulated (for keypads)